Skip to main content

Table 2 Performance of PHQ-9 at different cut-off points to detect Major Depressive Episode according to MINI

From: Validation and calibration of the patient health questionnaire (PHQ-9) in Argentina

PHQ-9 cutoff

Sensitivity %

Specificity %

PPV

NPV

LR+

LR-

Youden’s Index (J)

> = 6

93.14%

74.63%

84.82%

87.72%

3.67

0.09

0.68

> = 7

90.20%

82.09%

88.46%

84.62%

5.04

0.12

0.72

> = 8

88.24%

86.57%

90.91%

82.86%

6.57

0.14

0.75

> = 9

86.27%

86.57%

90.72%

80.56%

6.42

0.16

0.73

> = 10

81.37%

89.55%

92.22%

75.95%

7.79

0.21

0.71