Skip to main content

Table 4 Anatomical MRI

From: The multi-level outcome study of psychoanalysis for chronically depressed patients with early trauma (MODE): rationale and design of an international multicenter randomized controlled trial

Scan Parameters for 3.0T MRI Scanners

Siemens

Philips

Coil

64

32

Sequence

MPRAGE

3D Gradient Echo Turbo Field Echo factor = 130

Scan plane

Sagittal

Sagittal

Direction of frequency coding

H-F

S/I

Echo time

2.75 ms

2.8 ms

Inversion Preparation Time

920 ms

920 ms

Flip Angle

9

9

Bandwidth

190 Hz/pixel

206 Hz/pixel

Repetition time (or MPRAGE TR)

2000 ms

3000 ms

Field of View

256 mm

256 mm

Matrix

256 × 256

256 × 256

Slice thickness

1.0 mm

176 slices

1.0 mm

176 slices

Phase Field of View

1.0

1.0

Number of excitations

2

2

Time

9 min, 20 secs

9 min, 3 secs