Skip to main content

Table 6 Resting-State fMRI

From: The multi-level outcome study of psychoanalysis for chronically depressed patients with early trauma (MODE): rationale and design of an international multicenter randomized controlled trial

 

Siemens

Philips

Sequence

2D Gradient Echoplanar

2D Gradient Echoplanar

Scan plane

Axial Oblique, parallel to the AC-PC line

Axial Oblique, parallel to the AC-PC line

Echo time

34 ms

34 ms

Flip Angle

90o

90o

Repetition time

4630 ms

4630 ms

Field of View

24 cm

24 cm

Matrix

112 × 112

112 × 112

Slice thickness

2.4 mm

2.4 mm

Number of Volumes/Run

90

90

In-Plane Resolution

24 cm/112 × 24 cm/112 = 2.14 × 2.14 mm2

24 cm/112 × 24 cm/112 = 2.14 × 2.14 mm2

Number of Slices

60

60

Number of Runs

1

1

Time

7 min 11 s (1000 s)

7 min 11 s (1000 s)